steam更新dota2不动:Juniper?NetScreen?报警灯长亮的解决办法

来源:百度文库 编辑:偶看新闻 时间:2024/04/27 15:19:29

故障描述:

alarm 灯亮红灯(常亮),且重启后也不会灭掉。

官方解答:

------------------------------------------------

Mr. xxx

I’ve checked the description about the “alarm LED”,I’m sorry that “Juniper Network” doesn’t provide an official document about the bug of “alarm LED”.

Here are my suggestions toward this challenge:

 

At the first beginning, let the customer realize that:

The alarm LED is just a signal to notice the network administrator that there had attack but blocked by firewall.

 

The flowing is official description provide by Netscreen:

The alarm led can,The alarm message needs to be deleted first? From the command line interface (CLI):

clear alarm traffic [Enter]

clear alarm event [Enter]

Then, the LED will remain lit until the following CLI command is issued:

clear led alarm [Enter]

For ScreenOS 4.0.1r1 and higher, you dont need to clear the logs before you clear the led alarm?

 

The Reasons including:

Attacking; get alarm event

Virus;

CUP or Memory Usage; get alarm threshold

Logging is full; get log event

Session connection is too big;

 

To slake the LED: clear led alarm

To find out reasons:get alarm event

------------------------------------------------

 

简单说下:

1、  鉴于NetScreen此文发布时间较早,某些命令已不支持,反正我现在环境ScreenOS5.0、6.1是找不到get alarm event这个命令,但是可以通过其他命令来完成。

NetScreen-> get alarm ?

snapshot             show snapshot

threshold            shows the alarm threshold values

traffic              show traffic alarm info;

2、  报警灯的状态只有在命令行界面下才能够被清除,目前web管理还不支持这个功能;

3、  如果您使用的是ScreenOS 4.0.1r1以上版本的话,则不需要在清除报警灯状态前做清除报警事件日志的工作,只需要清除报警灯(clear led alarm)的状态就可以了;

4、  NetScreenOS的版本低的话,重起也会亮红灯(这个我没有碰到过,我所使用过的最低版本为4.0r6);

5、  NetScreen只要有alarm级别以上的日志产生,这个灯就会亮起来,而且不会自动灭掉;

 

    另:NetScreen的alarm级别日志,为NetScren事件日志级别中Emergency、Alert和Critical这3个级别日志的集合,详细情况见Juniper NetScreen事件日志级别分类。